|
PolyU Institutional Repository >
Health Technology and Informatics >
HTI Journal/Magazine Articles >
Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/2366
|
| Title: | Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition |
| Authors: | Xie, Hong-Bo Zheng, Yong-Ping Guo, Jing-Yi |
| Subjects: | Mechanomyogram Electromyogram Muscle activity classification Wavelet packet transform Singular value decomposition Prosthetic control |
| Issue Date: | May-2009 |
| Publisher: | IOP Publishing |
| Citation: | Physiological measurement, May 2009, v. 30, no. 5, p. 441-457. |
| Abstract: | Previous works have resulted in some practical achievements for mechanomyogram (MMG) to control powered prostheses. This work presents the investigation of classifying the hand motion using MMG signals for multifunctional prosthetic control. MMG is thought to reflect the intrinsic mechanical activity of muscle from the lateral oscillations of fibers during
contraction. However, external mechanical noise sources such as a movement artifact are known to cause considerable interference to MMG, compromising the classification accuracy. To solve this noise problem, we proposed a new scheme to extract robust MMG features by the integration of the wavelet
packet transform (WPT), singular value decomposition (SVD) and a feature selection technique based on distance evaluation criteria for the classification of hand motions. The WPT was first adopted to provide an effective time–frequency representation of non-stationary MMG signals. Then, the SVD and the distance evaluation technique were utilized to extract and select the optimal feature representing the hand motion patterns from the MMG time–frequency representation matrix. Experimental results of 12 subjects showed that four different motions of the forearm and hand could be reliably differentiated using the proposed method when two channels of MMG signals were used. Compared with three previously reported time–frequency decomposition methods, i.e. short-time Fourier transform, stationary wavelet transform and S-transform, the proposed classification system gave the highest average classification accuracy up to 89.7%. The results indicated that MMG could potentially serve as an alternative source of electromyogram for multifunctional prosthetic control using the proposed classification method. |
| Description: | DOI: 10.1088/0967-3334/30/5/002 |
| Rights: | © 2009 IOP Publishing Ltd. This is an author-created, un-copyedited version of an article accepted for publication in Physiological Measurement. IOP Publishing Ltd
is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at DOI:10.1088/0967-3334/30/5/002 |
| Type: | Journal/Magazine Article |
| URI: | http://hdl.handle.net/10397/2366 |
| ISSN: | 0967-3334 |
| Appears in Collections: | HTI Journal/Magazine Articles RIIPT Journal/Magazine Articles
|
Locate publisher version via
|
Facebook
del.icio.us
LinkedIn
All items in the PolyU Institutional Repository are protected by copyright, with all rights reserved, unless otherwise indicated. No item in the PolyU IR may be reproduced for commercial or resale purposes.
|
|