Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1795
Title: Volume reconstruction of freehand three-dimensional ultrasound using median filters
Authors: Huang, Qing-Hua
Zheng, Yong-Ping
Subjects: Freehand 3D ultrasound
3D ultrasound imaging
Median filter
Gaussian weighted median
Volume reconstruction
Issue Date: Jul-2008
Publisher: Elsevier
Source: Ultrasonics, July 2008, v. 48, no. 3, p. 182-192.
Abstract: Objectives: This paper aims to apply median filters for reducing interpolation error and improving the quality of 3D images in a freehand 3D ultrasound (US) system.
Background and motivation: Freehand 3D US imaging has been playing an important role in obtaining the entire 3D impression of tissues and organs. Reconstructing a sequence of irregularly located 2D US images (B-scans) into a 3D data set is one of the key procedures for visualization and data analysis.
Methods: In this study, we investigated the feasibility of using median filters for the reconstruction of 3D images in a freehand 3D US system. The B-scans were collected using a 7.5 MHz ultrasound probe. Four algorithms including the standard median (SM), Gaussian weighted median (GWM) and two types of distance-weighted median (DWM) filters were proposed to filter noises and compute voxel intensities. Qualitative and quantitative comparisons were made among the results of different methods based on the image set captured in freehand from the forearm of a healthy subject. A leave-one-out approach was used to demonstrate the performance of the median filters for predicting the removed B-scan pixels.
Results: Compared with the voxel nearest-neighbourhood (VNN) and distance-weighted (DW) interpolation methods, the four median filters reduced the interpolation error by 8.0–24.0% and 1.2–21.8%, respectively, when 1/4 to 5 B-scans was removed from the raw B-scan sequence.
Conclusions: In summary, the median filters can improve the quality of volume reconstruction by reducing the interpolation errors and facilitate the following image analyses in clinical applications.
Rights: Ultrasonics © 2008 Elsevier B.V. The journal web site is located at http://www.sciencedirect.com.
Type: Journal/Magazine Article
URI: http://hdl.handle.net/10397/1795
DOI: 10.1016/j.ultras.2007.11.005
ISSN: 0041-624X
Appears in Collections:HTI Journal/Magazine Articles

Files in This Item:
File Description SizeFormat 
3_D_US_using_Median_Filters_Huang_and_Zheng_ULTRASONICS_Nov_26_2007_revision final version.pdfPre-published version1.4 MBAdobe PDFView/Open


All items in the PolyU Institutional Repository are protected by copyright, with all rights reserved, unless otherwise indicated. No item in the PolyU IR may be reproduced for commercial or resale purposes.